Overview

Water carries electricity efficiently. When the two mix, the result can kill. Because of this, from an electrical safety point of view, the bathroom is possibly the most dangerous room in the home.

The consequences of an electric shock are far more severe in a bathroom or shower room as wet skin reduces the body’s resistance. There are special requirements for electrical installations in bathrooms.

Choosing a light that’s safe for the bathroom

Electrical equipment may be identified as having a certain level of mechanical and moisture protection, these are quoted as ‘Ingress Protection’ (or IP) numbers, such as ‘IPXY’, where X and Y are numbers, the X showing the level of mechanical protection and Y showing the level of moisture protection, in both cases, the higher the number, the better the protection.

If a piece of equipment does not have an IP number, it must not be used in zones 0, 1 or 2 (or elsewhere having a wet/damp environment).

The most common IP Codes are: IP67, IP65, IP44, IP20. For bathroom products you will find them clearly marked with its IP rating and the zone in which it can be installed, on some of the new fitting it will have a drawing on the box showing you where it can and can’t be fitted in the wetroom.

Typical electrical items which are marked with IP numbers include:

  • Extractor fans
  • Lighting
  • Heaters
  • Electrical shower units
  • Shower pumps

Safety Zones for a Bathroom

Zone 0

Inside the bath or shower. Any fittings used here must be SELV (Separated Extra Low Voltage) and have a minimum rating of IP67 (protected against immersion in water, total immersion proof).

Zone 1

Above the bath or shower to a height if 2.25m. A minimum rating of IP44 is required. In this zone, if there is likelihood of water jets being used for cleaning purposes, a minimum of IPX5 is required.

Also, subject to IP rating, SELV or 230 V luminaries may be used in this zone; if the fitting is 230 volts, a 30mA residual current device (RCD) must also be used to protect the circuit in this zone.

Zone 2

The area stretching to 0.6m outside the bath or shower and above the bath or shower if over 2.25m. An IP rating of at least IP44 is required. In this zone, if there is likelihood of water jets being used for cleaning purposes, a minimum of IPX5 is required.

Also, subject to IP rating, SELV or 230 V luminaries may be used in this zone. In addition, it is a good practice to also consider the area around a wash basin (within a 60cm radius of any tap) as Zone 2.

Outside the zones, anywhere outside zones 0, 1, and 2. Where water jets are not to be used for cleaning purposes, the general rules of BS 7671 apply. Here, there is no requirement for any lighting solutions to be protected against particles or solid objects, e.g. IPX4, no IP rating required.

RCD Protection

The 18th Edition IET Wiring Regulations require that additional protection shall be provided for all circuits by the use of RCDs having the characteristics specified in Regulation 415.1.1.

Regulation 701.411.3.3 means that all circuits, including lighting, electric showers, heated towel rails, etc., will require RCD protection, not exceeding 30mA.

Supplementary equipotential bonding

The Regulation states that where the location containing a bath or shower is in a building with a protective equipotential bonding system, supplementary equipotential bonding may be omitted where all of the following conditions are met:

  1. All final circuits of the location comply with the requirements for automatic disconnection of supply,

  2. All final circuits of the location have additional protection by means of an RCD,

  3. All extraneous-conductive-parts of the location are effectively connected to the protective equipotential bonding.

Sockets

  • Sockets are not allowed in bathrooms or shower rooms (apart from shaver-supply units), unless they can be fitted at least 2.5 metres from the boundary of zone 1.
  • Shaver-supply units must be a safe distance from the bath or shower to avoid splashes

Lights

  • Enclosed ceiling lights are preferable to pendant (ones that hang down) light fittings. All light fittings, that are not enclosed, should be out of reach of someone using, or still wet from using, the bath or shower.
  • A ceiling-mounted pull-cord switch with the cord made of insulating material is the safest option for a bathroom. Standard wall-mounted light switches are a possible danger because of dampness and wet hands.

Heaters and towel rails

  • Central heating is the safest way of keeping a bathroom warm. But, if you do have an electric room heater, it must be fixed at a safe distance from the bath or shower.
  • Electric and gas water heaters in a bathroom must be fixed and permanently wired, unless they are powered by a socket fitted at least 2.5 metres from the boundary of zone 1.
  • Electric heaters should preferably be controlled by a pull cord or a switch outside the bathroom.

Showers

An electric shower must be supplied on its own circuit direct from the consumer unit.

Bring mains-powered portable appliances such as hairdryers, heaters or radios into a bathroom. You could be severely injured or die. You can get a fixed hairdryer with hot air delivered through a flexible plastic pipe installed in bathrooms.

DON’T

Bring mains-powered portable appliances such as hairdryers, heaters or radios into a bathroom. You could be severely injured or die. You can get a fixed hairdryer with hot air delivered through a flexible plastic pipe installed in bathrooms.

Why use us?

All our electricians and staff are uniformed and carry company identification.

ProElec’s electricians are qualified to the 18th Edition IET Wiring Regulations and City & Guilds 2391 Inspection & Testing. (Certification of Electrical Installations).

More information

For more information please contact us or telephone us directly on 01925 222197

Are you looking for a local and reliable electrician in the Newton-le-Willows, St Helens, Warrington and Wigan area?

Are you looking for a local and reliable electrician? Please contact us.

Get in touch